M. PARAMETERS
B–66102E/10
APPENDIX
204
= 1 : Extension P-CODE variable #20000 is the fixed decimal
format
XDIL = 0 : Axis interlock function invalid
= 1 : Axis interlock function valid
DAUX = 0 : Does not make the CUSTOM screen appear at power on
= 1 : Makes CUSTOM screen appear at power on
PWSR = 0 : P CODE work number search function invalid
= 1 : P CODE work number search valid
EXT1 = 0: Extension functions invalid
= 1: Extension functions valid (RS-232-C control, NC
program access)
CAUTION
When EXT1=1, part program memory reduces by 1.63m
D Series 16/18–A (part program storage of up to 80m)
D Series 20 (part program storage of up to 80m)
D Series 21–MB (D201 series, part program storage of up
to 80m)
D Series 21–TB (control unit A)
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
9003 PTCR KY20 HRGR ONMSK
ONMSK= 0 : The O and N numbers are displayed on the CUSTOM
screen.
= 1 : The O and N numbers are not displayed on the CUSTOM
screen.
HRGR = 0 : Standard mode graphic display
= 1 : High resolution graphic mode display (set to H1I
usually)
KY20 = 0 : Not +a to #8501 with decimal point input by key input
variables
= 1 : +a to #8501 with decimal input by key input variables
(+a: +20 for a display with 7 soft keys, +40 for a display
with 12 soft keys)
PTCR = 0 : Does not output ”CR” code twice in P-CODE variable
outputting
= 1 : Output ”CR” code twice in P-CODE variable outputting
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
9004 CUTLG NOP_B HRGC IMG SP_G_C SP_G_B
SP_G_B, SP_G_C
00 : Standard G code system
01 : G code system B
10 : G code system C
11 : G code system C