B–66102E/10
M. PARAMETERS
APPENDIX
197
Address
8538 Call code of subprogram call by a range specification M code (lower limit)
8539 Call code of subprogram call by a range specification M code (upper limit)
Valid data range : 1 to 9999
These parameters specify the range of call codes of
subprogram calls by a range specification M code.
NOTE
1 If a value beyond the range is specified or if the value of
parameter 8538 is greater than the value of parameter
8539, the subprogram call by a range specification M code
is disabled.
2 M30, M98, M99, and M codes used for macro and
subprogram calls are not used as call codes even if the
codes are included in the specified range.
Address
8540 Transmission/reception wait time–out period (s)
Valid data range : 0 to 180
This parameter specifies a time–out period for the
transmission/reception wait state brought by the
send/receive function (G335 to G338) under
reader/puncher interface control. If 0 is specified, no
time–out occurs.
Address
8544 Call address of subprogram call by a special code (O9004)
8545 Call address of subprogram call by a special code (O9005)
Valid data range : 65(A) to 90(Z) (excluding O, N, P, L, G, and axis
names)
These parameters specify call addresses of
subprogram calls by a special code.