M. PARAMETERS
B–66102E/10
APPENDIX
200
The bits of the parameters select different axes.
No.8555
X01 : First axis
X02 : Second axis
:
No. 8504 :
X24 : Twenty–fourth axis
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
8558 ACA P98 15I PWT XDL ACS
ACS = 0 : A macro call by an axis address always calls O9009.
= 1 : A macro call by an axis address calls a program
depending on the axis.
First axis ! Calls O9031.
Second axis ! Calls O9032.
:
n–th axis ! Calls a program having an O number of
9030 + n.
XDL = 0 : Interlock along an axis is disabled.
= 1 : Interlock along an axis is enabled.
PWT = 0 : The conversational macro function is not executed at
power–up.
= 1 : The conversational macro function is executed at
power–up.
The position display screen is normally displayed at
power–up, but the conversational macro function can be
executed to display a special screen.
15I = 0 : The macro executor function follows Series 15–B
compatible specifications.
= 1 : The macro executor function follows original
specifications for the Series 15i.
This bit selects the following specifications:
Function
Series 15–B specifications
(15I = 0)
Series 15i specifica-
tions (15I = 1)
Character coordi-
nate system
X0 to 73, Y0 to 26 X0 to 79, Y0 to 26
System display part
Soft key frame
FS15–B FS15i
Key input line Y22 Y23
Command key input
variable by parame-
ter 8501
The INSERT, ALTER, and
DELETE keys cannot be
read.
The keys can be read.
INSERT : 31
ALTER : 32
DELETE : 33
Method of execut-
ing both auxiliary
macro and con-
versational macro
Sequential execution (After
the program end command of
the auxiliary macro is
executed, the conversational
macro is executed.)
Parallel execution
Alarm information of
window function
(foreground PS
alarm of alarm basic
flags)
When a foreground PS alarm
or MC alarm is issued
When a foreground PS
alarm is issued. An
MC alarm can be read
with basic flag 2.)