3.OPERATION PROFIBUS CONFIGURATION TOOL B-64174EN/01
- 76 -
Setting item
The following parameters consist of parameters dependent on the baud
rate.
Item Description
Set a baud rate. Baudrate
Range: 9.6Kbps, 19.2Kbps, 93.75Kbps, 187.5Kbps,
500Kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps
Set a slot time.
This value specifies a maximum allowable time from
transmission of a token frame until the first character of
a response frame is read.
T sl
Range: 1 to 65535 (Unit: Bit time)
Set a minimum station delay time of responders.
This value specifies a minimum allowable elapsed time
from the last bit of send or receive data to the start bit of
the next send or receive data.
min T sdr
Range: 1 to 65535 (Unit: Bit time)
Set a maximum station delay time of responders.
This value specifies a maximum allowable elapsed time
from the last bit of send or receive data to the start bit of
the next send or receive data.
max T sdr
Range: 1 to 65535 (Unit: Bit time)
Set a transmitter fall/repeater switch time.
This value specifies a wait time from reception of data
until the receiver is actuated.
T qui
Range: 0 to 255 (Unit: Bit time)
Set a setup time.
This value specifies a time from the occurrence of an
event until an action is started for the event.
T set
Range: 0 to 255 (Unit: Bit time)
Set a target rotation time.
This value specifies an estimated time to be used for the
PROFIBUS token to make one rotation.
T tr
Range: 1 to 16777215 (Unit: Bit time)
Set a gap update factor.
This value specifies the number of tokens that are
passed in a GAP maintenance period.
G
Range: 1 to 100
Set a highest station address.
This value specifies a maximum node number to be set
on the PROFIBUS network to be connected with.
HSA
Range: 2 to 126
Set the maximum number of retries.
This value specifies the maximum allowable number of
retries.
max retry limit
Range: 1 to 8