B-63644EN/02 IV. OPERATION 6.15i
i i
i DATA SERVER FUNCTIONS
- 261 -
For DNC operation by a subprogram call (M198) in storage mode
Procedure
1 Place the CNC in MEM mode.
2 Display the Hard Disk File Directory screen and move to the
directory holding an NC program to be called by a subprogram.
3 Press the operation menu key at the right end of the soft key menu.
4 Press soft key [M198 DIR SET].
5 Press soft key [EXEC]. The current work directory name is
displayed in M198 DIRECTORY on the screen.
6 The NC program containing the M198 directive is automatically
executed.
NOTE
1 DNC operation by a subprogram call (M198) cannot
be executed concurrently with NC program input, NC
program output, and DNC operation.
2 The file name of the subprogram to be called during
DNC operation by a subprogram call (M198)
becomes Oxxxx if the O number is between 1 and
9999. If the O number is between 10000 and
9999999, the file name becomes Oxxxxxxx. If the O
number is between 10000000 and 99999999, the file
name becomes xxxxxxxx.
3 Assume that a subprogram call is further performed
in the subprogram called by the DNC operation by a
subprogram call (M198). If the subprogram to be
called exists in tape memory, it can be executed as a
subprogram. If, however, this subprogram exists on
the Fast data server built-in ATA card, it cannot be
executed as a subprogram.
4 When viewed from the CNC, the data server
functions are handled in the same way as other
input/output equipment. So, the subprogram call
restrictions are equivalent to those for other
input/output equipment.