10/21
TITLE
Addition of Machine Remote Diagnosis
and Unsolicited Message
4. Control of Machine Remote Diagnosis with using PMC signals
Passing through PMC signals, a ladder program can control the start/stop of Machine Remote
Diagnosis, and can monitor the status.
4.1. Signals
Address # 7 # 6 # 5 # 4 # 3 # 2 # 1 # 0
G141
DIAREQ DIASTP INQU2 INQU1 INQU0
Inquiry number signals
INQU0,INQU1,INQU2 <G0141#0 to #2>
[Classification] Input signal
[Function] Destination (Inquiry number) of the request of Machine Remote
Diagnosis
[Operation] The destination can be selected as follows
INQU2 INQU1 INQU0 Meaning
0 0 0 Not selected
0 0 1 Inquiry 1
0 1 0 Inquiry 2
0 1 1 Inquiry 3
Machine Remote Diagnosis request signal
DIAREQ <G0141#5>
[Classification] Input signal
[Function] Request of starting Machine Remote Diagnosis
[Operation] This signal requests the start of Machine Remote Diagnosis towards the
inquiry which is specified by INQU0-INQU2.
This signal needs to be reset when the RMTEND signal or the
RMTCAN signal becomes active.
SHEETDESCRIPTIONDESIGN DATE EDIT
01
02.06.21
Mutai First issue
B-63644EN/02-3
FANUC LTD.
DRAW.NO.