B-63644EN/02 III. SETTING 1.FACTOLINK FUNCTIONS FOR THE 16i/18i/21i
- 29 -
1.3 PARAMETERS
The following describes the parameters related to the FACTOLINK
functions.
Parameters
0802 Communication channel
[Data type] Byte
[Valid data range] 11 to 13
11: Selects IP address 1.
12: Selects IP address 2.
13. Selects IP address 3.
#7 #6 #5 #4 #3 #2 #1 #0
0810 MONO TIME BGS
[Data type] Bit
BGS Performs the following when the FACTOLINK screen is not displayed.
1: Enables logging in the background.
0: Disables logging.
TIME Selects the time display format.
1: "97/11/12 00:00" format
0: "Wed Nov 12 00:00:00" format
MONO FACTOLINK screen display color
1: Monochrome
0: Color
0811 Communication channel
[Data type] Byte
[Valid data range] 0, 1, 10, 20, 21
0 : "D" address area
1 : "R" address area
10: Fixed data only
20: "D" address area + fixed data
21: "R" address area + fixed data
0812 PMC address of logging data
[Data type] Word
[Valid data range] 0 to 65535
Sets the leading PMC address value where logging data is stored.