5/21
TITLE
Addition of Machine Remote Diagnosis
and Unsolicited Message
For Series 16i/18i/21i-B
0024 Port for PMC Ladder Development Tool
[Data type] Byte type
[Range] 0 to 255
10: HIGH SPEED I/F(Ethernet port) is used for PMC Online Editor
#7 #6 #5 #4 #3 #2 #1 #0
904 DNS
[Data type] Bit type
DNS
1: Available
0: Not available
NOTE
1. To use the DNS function, the IP address of DNS server should be set to
[DNS IP address] of Ethernet parameter screen of CNC.
#7 #6 #5 #4 #3 #2 #1 #0
3206 NS2 S2K
[Data type] Bit type
NS2 Dual CNC Screen Display function
1: Available
0: Not available
S2K Key control of Dual CNC Screen Display operation
1: If a touch panel is used, the Key control can be switched by pushing the upper left
courner of the screen.
0: The Key control can be switched by the DI signal (G0295#7)
#7 #6 #5 #4 #3 #2 #1 #0
8706 SLRMT
[Data type] Bit type
SLRMT Machine Remote Diagnosis
1: Machine Remote Diagnosis can communicate via Fast Ethernet/Fast DataServer
0: Machine Remote Diagnosis can communicate via Embedded Ethernet
CNC should be rebooted when the parameter is changed.
SHEETDESCRIPTIONDESIGN DATE EDIT
01
02.06.21
Mutai First issue
B-63644EN/02-3
FANUC LTD.
DRAW.NO.