9/21
TITLE
Addition of Machine Remote Diagnosis
and Unsolicited Message
Explanation of Error number and Error message
No Error message Meaning
1
“ Diagnosis is busy.”
Machine Remote Diagnosis is already starting.
2
"Router isn't alive."
Router seems not active.
(The cable may not be being connected, or the switch of router
may not be active)
3
"Receipt Server isn't alive."
The package seems not active.
The package does not answer against the request from CNC.
4
"System error."
System error occurred at CNC
5
"Invalid Inquiry number."
Inquiry number is not correct.
Please check it.
6
"Invalid IP Address."
IP address of the package is not correct.
Please check it.
7
"Invalid PORT number."
the port number is not correct.
Please check it.
8
"Invalid Router IP Address."
IP address of Router is not correct.
Please check it.
9
"Socket error."
Transmission of data was failed.
10
(Reserved)
11
"Invalid Request."
Internal error of Machine Remote Diagnosis occurs at CNC.
12
"Invalid Packet."
Invalid data was received from the package.
13
"Diagnosis was already
stopped."
Though Machine Remote Diagnosis was not running, soft key
[CLOSE] was pressed.
14
"Download error."
The error occurred during NC program-download.
15
"DNC error." The error occurred during DNC operation.
16
"Upload error." The error occurred during NC program-upload.
17
"Receive error." The receiving of data failed.
18
"VGA error." The error occurred during the graphic-related process.
19
"HeartBeat timeout." Time out occurred during the data exchange of the
heart-beat packets between PC and CNC.
20
"HeartBeat error." A heart-beat packet can not be sent.
21
"Prepare error." The connection packet of Machine Remote Diagnosis
cannot be sent.
22
"DNS error." The specified PC(Machine Remote Diagnosis Package)
is not found.
SHEETDESCRIPTIONDESIGN DATE EDIT
01
02.06.21
Mutai First issue
B-63644EN/02-3
FANUC LTD.
DRAW.NO.