2.DNC1/Ethernet FUNCTIONS FOR THE 16i/18i/21i/PMi III. SETTING B-63644EN/02
- 38 -
Display items and setting items
Display items related to the Ethernet functions
The items related to the Ethernet functions are displayed.
Item Description
MAC ADDRESS MAC address of the Fast Ethernet board
NUMBER OF
SCREENS
Total number of Ethernet error message screens used
by the Ethernet functions
MAXIMUM PATH Number of control systems in the CNC
HDD EXISTENCE Indicates whether ATA flash card is mounted on the fast
data server.
0: Not mounted.
2: Mounted.
TCP/IP setting items for the CNC
Set the TCP/IP items for the CNC.
Item Description
IP ADDRESS Specifies the IP address of the CNC.
(Format: "192.168.0.1")
SUBNET MASK Specifies the mask address of the network IP address.
(Format: "255.255.255.0")
ROUTER IP
ADDRESS
Specifies the router IP address.
Specify this address when the network incorporates a
router.
(Format: "192.168.0.99")
DNC1/Ethernet setting items
Set the items related to the DNC1/Ethernet server.
Item Description
PORT NUMBER
(TCP)
Specifies the port No. to be used by the DNC1/Ethernet
functions within a range of 5001 to 65535.
This port No. must match the "NC TCP port No." on the
personal computer's Machine Setup screen.
For details of how to set this, refer to the " FA SYSTEM
for PC WindowsNT version, OPERATOR'S MANUAL
(B-75044EN)."
PORT NUMBER
(UDP)
Specifies the port No. to be used by the DNC1/Ethernet
functions, within a range of 5001 to 65535.
This port No. must match that of the
"FANUC_C4_SERVER" in the personal computer's
"services" file.
For details of how to set this, refer to the "FANUC FA
SYSTEM for PC WindowsNT version OPERATOR'S
MANUAL (B-75044EN)."
TIME INTERVAL Specifies the interval at which broadcasting is
performed in 10 ms units within a range of 0 to 65535.
If "0" to "9" is set as the interval, broadcasting is not
performed. In other words, an interval of less than 100
ms cannot be set.
Example:
100: Broadcasting is carried out every one second
[1000 ms] (= 100 × 10).