1.FACTOLINK FUNCTIONS FOR THE 16i/18i/21i III. SETTING B-63644EN/02
- 26 -
Item Description
IP ADDRESS 3 Specifies the IP address of the personal computer to be
accessed by the FACTOLINK functions.
(Format: "192.168.0.103")
PORT NUMBER 3 Specifies the port No. to be used by the FACTOLINK
functions within a range of 5001 to 65535.
This port No. must match "ocsnc" in the personal
computer's "services" file.
For details of how to set this, refer to the "FANUC
FACTOLINK Script Function, OPERATOR'S MANUAL
(B-75054EN)."
NOTE
When the "TCP/IP setting items for the CNC" have
been changed, the power must be turned off then on
again.