6.15i
i i
i DATA SERVER FUNCTIONS IV. OPERATION B-63644EN/02
- 284 -
6.11.3 Switching Data Server Modes
Switch data server modes.
Procedure
1 Place the CNC in MDI mode.
2 Press function key
SYSTEM
.
3 Press soft key [CHAPTER].
4 When you press soft key [MIN DATA SERVER], the Data Server
(Maintenance) screen appears.
5 To change to storage mode, press soft key [STORAGE MODE].
To change to FTP mode, press soft key [FTP MODE].
To change to buffer mode, press soft key [BUFFER].
6 Press soft key [EXEC].
NOTE
Operations in the buffer mode need the optional
buffer mode functions.