Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
31/67
page
Title
Draw
a tool whose life has not expired is selected from a specified group, and the tool life counter
is incremented by one. This enables the tool life to be counted by a tool group command (T
code) even when the command is not the first tool group command issued since the CNC
enters the automatic operation start state from the reset state. The tool life count restart M
code is specified in parameter No. 6811.
Example: Suppose that M16 is a tool life count restart M code.
Also suppose that the life count is specified by use count.
T199 ; A tool whose life has not expired is selected from group 1.
: Tool life management is performed for group 1.
: (The tool life counter is incremented by one.)
:
T299 ; A tool whose life has not expired is selected from group 2.
: Tool life management is performed for group 2.
: (The tool life counter is incremented by one.)
:
M16 ; Tool life counting is restarted.
T199 ; A tool whose life has not expired is selected from group 1.
: Tool life management is performed for group 1.
: (The tool life counter is incremented by one.)
NOTE
1 The tool life count restart M code is treated as an M code not
buffered.
2 If the life count type is the use count specification type, the tool
change signal is output if the life of at least one tool group has
expired when the tool life count restart M code is specified. If the life
count type is the duration specification type, specifying the tool life
count restart M code causes nothing.