FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
50/67
page
Title
Draw
- A new tool of a tool group specified with a tool group number by a T code command is
selected because the life of the tool used so far in the group has expired.
After the code signal for the new tool is sent, TLNW is set to "1" at the same time when
tool function strobe signal TF is sent.
The signal is set to "0" when:
- Completion signal FIN for strobe signal TF is set to "1" when TLNW is "1".
T command
Code signal T0-T31
Strobe signal TF
New tool select signal
TLNW
Completion signal FIN
Tool group number selection signals TL01 to TL512 <Gn047#0 to Gn048#1>
[Classification] Input signals
[Function] These signals specify a tool group number. Before tool change reset signal
TLRST or tool skip signal TLSKP is input, the target group for the tool change
reset operation or tool skip operation is specified with these signals.
[Operation] The table given below shows the correspondence between tool group numbers
and the tool group signals by providing several examples. A binary number
plus 1 indicates a tool group number. A group with a specified number is then
selected.