Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
36/67
page
Title
Draw
When the arbitrary group number function is enabled, an arbitrary group number is indicated
in parentheses beside a tool group number. When no arbitrary group number is set,
"********" is indicated.
Fig. 1.2 (b) Display of an arbitrary group number
Arbitrary group numbers are made usable by setting the following parameters:
- The tool life management B function is enabled
(bit 4 (LFB) of parameter No. 6805 = 1).
- The arbitrary group number function is enabled
(bit 5 (TGN) of parameter No. 6802 = 1).
- The tool change type is the ATC type (bit 3 (TCT) of parameter(No. 5040 = 1).
- The tool life management B function is enabled
(bit 4 (LFB) of parameter No. 6805 = 1).
- The arbitrary group number function is enabled
(bit 5 (TGN) of parameter No. 6802 = 1).
- Explanation of (C)
Tool group numbers for which the tool change signal is output are indicated.
When there are too many tool group numbers to display, ">>" is indicated at the end of the
displayed tool group numbers.
When there is no tool group number for which the tool change signal is output, "****" is
indicated.
NOTE
If the arbitrary group number function is enabled, the group number
of the group to be changed is indicated by its arbitrary group number
instead of the tool group number.