Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
42/67
page
Title
Draw
- OPTION GROUP: Arbitrary group number
(When bit 5 (TGN) of parameter No. 6802 = 1)
- RESET COUNT: Remaining life setting till a new tool is selected
(When bit 3 (GRP) of parameter No. 6802 = 1)
1.2.2.2 Setting data on the group edit screen
Tool life management data can be set in the reset state (the OP signal is "0", and the RST
signal is "0"). By setting bit 1 (TCI) of parameter No. 6804 to 1, tool life management data
can be set during automatic operation (the OP signal is "1").
The following edit operations are allowed:
Allowable edit operation Mode
Setting the life count type, life value, tool life counter, and
tool data (T, H, or D code)
All modes
Adding a tool number (T code) MDI
Deleting all tool group data at a time MDI
Deleting tool data (state, T code, H code, or D code) MDI
Skipping a tool MDI
Clearing the life count (resetting the life) MDI
Allowable edit operation Mode
Setting the life count type, life value, tool life counter, and
tool data (T or D code)
Setting of D code is allowed only when the ATC type is
used (bit 3 (TCT) of parameter No. 5040 = 1).
All modes
Adding a tool number (T code) MDI
Deleting all tool group data at a time MDI
Deleting tool data (state, T code, or D code) MDI
Skipping a tool MDI
Clearing the life count (resetting the life) MDI