Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
39/67
page
Title
Draw
1.2.2 Tool Life Management (Group Edit Screen)
On the group edit screen, you can edit tool life management data (such as the tool life value,
tool life counter, and tool data) in a group.
1.2.2.1 Displaying the group edit screen
Follow the procedure below to display the group edit screen:
(1) On the list screen, place the cursor to the tool group you want to edit.
(2) Press the [(OPRT)] soft key.
(3) Press the [EDIT] soft key.
Fig. 1.2 (c) Display of tool life management (group edit screen)
- Explanation of (A)
Like the list screen, the group edit screen displays tool group numbers and an override value
for the items listed below. When there is no pertinent tool group, **** is displayed instead
of a tool number.
NEXT GROUP: Tool group number for which life counting is to be started by the
next M06 command
USING GROUP: Tool group number for which life counting is currently performed
SELECTED GROUP: Tool group number for which life counting is currently
performed, or tool group number for which life counting was
performed most recently
NOTE
When no tool is registered for a tool group, the life count type, life
value, and tool life counter value are not indicated.
(A)
(B)