# 3 SIG When a tool is skipped by a signal, the group number is:
0: Not input by the tool group number selection signals.
1: Input by the tool group number selection signals.
NOTE
When this parameter is set to 0, a tool of the currently used
group is skipped.
# 4 GRS When the tool change reset signal (TLRST) is input:
0:
If the life of the group specified by the tool group number selection signals has
expired, the execution data of the group is cleared.
1: The execution data of all registered groups is cleared.
If this parameter is set to 1, the execution data of all registered groups is cleared
also when the clear operation to clear execution data is performed on the tool life
management list screen.
# 5 SNG When the tool skip signal (TLSKP) is input while a tool not controlled
by the tool life management function is being used:
0: A tool of the most recently used group or a specified group (bit 3 (SIG) of
parameter No. 6800) is skipped.
1: The tool skip signal is ignored.
# 6 IGI Tool back numbers are:
0: Not ignored.
1: Ignored.
# 7 M6T A T code specified in the same block as M06 is:
0: Assumed to be a back number.
1: Assumed to be a command specifying the next tool group.
#7 #6 #5 #4 #3 #2 #1 #0
M6E EMD LVF TSM
6801
M6E EMD LVF
[Input type] Parameter input
[Data type] Bit path
# 1 TSM In the tool life management function, life counting is performed as
follows when more than one offset is specified:
0: Counting is performed for each tool number.
1: Counting is performed for each tool.