Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
63/67
page
Title
Draw
6810
Tool life management ignore number
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 0 to 99999999
This parameter sets the tool life management ignore number.
When the value specified in a T code exceeds the value set in this parameter, the
value obtained by subtracting the parameter-set value from the T code value is
assumed to be the tool group number for tool life management.
6811
Tool life count restart M code
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to 255 (except 01, 02, 30, 98, and 99)
When 0 is specified, it is ignored.
When the life is specified by count, the tool change signal (TLCHA)
life of at least one tool group has expired when the tool life count restart M code is
issued.
The T code (tool life management group command) specified after the tool life
count restart M code selects a tool whose life has not expired from a specified
group, and the next M06 command increments the tool life counter by one.
When the life is specified by duration, specifying the tool life count restart M code
causes nothing. When 0 is set in this parameter, the tool life count restart M code
is invalid.