When the tool life management B function is enabled (bit 4 (LFB) of parameter No. 6805 =
1), arbitrary groups and remaining life setting are displayed by setting the following
parameters:
- When bit 5 (TGN) of parameter No. 6802 = 1:
Arbitrary groups are displayed on the list screen and the group edit screen.
- When bit 3 (GRP) of parameter No. 6802 = 1:
The remaining life setting is displayed on the group edit screen.
The group edit screen always shows the H and D codes.
In the T series, there are two tool change types, the turret type and the ATC type, and the
displayed items vary depending on the tool change type used.
For the turret type (bit 3 (TCT) of parameter No. 5040 = 0)
- The H and D codes are not used, so they are not displayed.
- Arbitrary groups cannot be used, so they are not displayed.
For the ATC type (bit 3 (TCT) of parameter No. 5040 = 1)
- The D code is displayed on the group edit screen.
- When the tool life management B function is enabled (bit 4 (LFB) of parameter No. 6805
= 1) and bit 5 (TGN) of parameter No. 6802 is set to 1, arbitrary groups are displayed
on the list screen and the group edit screen.
When the tool life management B function is enabled (bit 4 (LFB) of parameter No. 6805 =
1) and bit 3 (GRP) of parameter No. 6802 is set to 1, the remaining life setting is displayed
on the group edit screen.