Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
59/67
page
Title
Draw
#1 TCO
#2 E17
Specifies whether to allow the FOCAS2 or PMC window function to write tool
information of a group being used or a group to be used next during automatic
operation (the OP signal is set to "1").
6802#1(TCO)
1
6802#2(E17)
Condition
0
1 0
Tool being used
× △ ○
to be used next
Tool not being
used
× ○ ○
During
automatic
operation
Group neither being used nor to be
used next
○ ○ ○
Not during automatic operation
○ ○ ○
○: Tool information can be written from FOCAS2 and PMC window.
×: Tool information cannot be written from FOCAS2 and PMC window.
When an attempt is made to write tool information from PMC window,
completion code 13 (REJECT ALARM) is returned.
△: Tool information cannot be cleared.
NOTE
When tool information of a tool being used (marked with "@") in
the group being used or to be used next or tool information of
the most recently used tool (marked with "@") in a group that is
neither the group being used nor the group to be used next is
cleared, the life counter is reset to 0.
It is possible to modify tool information of a tool in the group to
be used next. However, because tool selection is already
completed, the selected tool does not change even when the
tool information is modified.
This parameter has no influence on modifications to tool
information by edit operations from the tool life management
screen.
# 3 GRP Management data of tool life arrival notice signal TLCHB is:
0: Managed using the remaining life value set in parameter Nos. 6844 and 6845.
1: Managed using the remaining life value set in tool life management data.
NOTE
When the tool life arrival notice signal function is used, bit 4
(LFB) of parameter No. 6805 must be set to 1 to enable the tool
life management B function.