Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
64/67
page
Title
Draw
6813
Maximum number of groups in tool life management
NOTE
After this parameter has been set, the power must be turned off then back
on for the setting to become effective.
[Input type] Parameter input
[Data type] Word path
[Unit of data] Group
[Valid data range] 0, 8, 16 to 256
This parameter sets the maximum number of groups to be used for each path. As
the maximum number of groups, set a multiple of eight. When the tool life
management function is not used, 0 must be set. Set this parameter so that the
total number of groups in all paths does not exceed the total number of groups in
the entire system (256 groups).
NOTE
When the power is turned on, all tool life management file data
is initialized. So, tool life management data must be set for all
paths that use tool life management.
6844
Remaining tool life (use count)
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to 9999
This parameter sets a remaining tool life (use count) used to output the tool life
arrival notice signal when the tool life is specified by use count. If a value greater
than the tool life value or 0 is set in this parameter, the tool life arrival notice signal
is not output.