- Setting the life count type, tool life value, tool life counter value, tool data, arbitrary group
number, and remaining life value
Setting the life count type, tool life value, tool life counter value, tool data, arbitrary group
number, and remaining life value
Procedure 1
(1) Position the cursor on the data item to be set.
(2) Type a value.
(3) Press the [INPUT] soft key.
Procedure 2
(1) Position the cursor on the data item to be set.
(2) Type a value.
(3) Press the INPUT key.
NOTE
1 Even when the tool life value and tool life counter value are changed,
the tool status and tool change signal are not affected.
2 When the life counter type is changed, the tool life value and tool life
counter value are set to 0.
When the tool life management B function is enabled (bit 4 (LFB) of parameter No. 6805 =
1), and the following parameters are valid, an arbitrary group and a remaining life value can
be set:
OPTION GROUP: Arbitrary group number
(When bit 5 (TGN) of parameter No. 6802 = 1)
RESET COUNT: Remaining life setting until a new tool is selected
(When bit 3 (GRP) of parameter No. 6802 = 1)
When the tool life management B function is enabled (bit 4 (LFB) of parameter No. 6805 =
1):
Turret type (bit 3 (TCT) of parameter No. 5040 = 0)
- OPTION GROUP: Cannot be set.
- RESET COUNT: A remaining life value until a new tool is selected can be set.
(When bit 3 (GRP) of parameter No. 6802 = 1)
ATC type (bit 3 (TCT) of parameter No. 5040 = 1)
- OPTION GROUP: An arbitrary group number can be set.
(When bit 5 (TGN) of parameter No. 6802 = 1)