Edit
Apprv.
Desig.
Design
FANUC Series 30i/31i/32i−MODEL A
Tool Life Management
Specifications
Sep.10.’04
61/67
page
Title
Draw
# 1 TCI During automatic operation (the OP signal is "1"), editing of tool life
data is:
0: Disabled.
1: Enabled.
NOTE
When this parameter is set to 1, tool life data can be edited
even during automatic operation (the OP signal is "1"). If the
target group for editing is the group being used or the group to
be used next, however, only presetting of the life counter is
permitted, and other data cannot be modified.
#7 #6 #5 #4 #3 #2 #1 #0
6805
TAD TRU TRS LFB FGL FCO
[Input type] Parameter input
[Data type] Bit path
# 0 FCO
If the life count type is the duration specification type, the life is counted
as follows:
0: Every second.
1: Every 0.1 second.
According to the setting of this parameter, the increment system of life values and
tool life counter values displayed on the tool life management screen is set as
follows:
Parameter FCO 0 1
Increment system for display and
setting of life values and life counter
values 1-minute increments 0.1-minute increments
NOTE
After changing the setting of this parameter, set data again by
(registration after deletion of data of all groups)
# 1 FGL If the life count type is the duration specification type, life data
registered by G10 is:
0: In one-minute increments.
1: In 0.1-second increments.