B–63835EN/03
1. DISPLAY AND OPERATION
137
(2)Remaining service time
The remaining service time of an item (the time allowed before the
item is replaced) is determined by count–down and displayed under
“Remaining service time.” When the remaining service time
decreases to a specified percentage (specified in parameter No. 8911)
of the service life or lower, it is displayed in red.
Count–down continues even after the service life has expired.
First place the cursor on the remaining service time of a target
registration number, enter a desired remaining service time value
using numeric keys, then press soft key [INPUT] (or the
INPUT
key).
Pressing soft key [+INPUT] adds the newly specified remaining
service time to the previously specified remaining service time.
The valid data range for the remaining service time is: 0 to (service
life)
After soft key [CLEAR] is pressed, pressing soft key [EXEC] sets the
remaining service time with the same value as for the service life.
NOTE
1 An attempt to set up the remaining service time for a non–
registered item or an item for which the service life has not
been set up results in the warning message “EDIT
REJECTED”.
2 An attempt to enter a value that is out of the valid data range
results in the warning message “DATA IS OUT OF RANGE”.
3 An attempt to enter a value that would make the remaining
service time 0 or lower, it is clamped at 0.
4. Pressing soft key [TYPE] results in the warning message
“EDIT REJECTED”.
(3)Count type
The type of a selected count method is specified under “Count type.”
After the cursor is placed on the count type of a target registration
number, pressing soft key [TYPE] displays the next count type as a
soft key. Select it and press soft key [EXEC].
Soft key Meaning Display
[NO CNT] Not counting (suspended). —
[ ALL ] Always count. All times
[PWR ON] Count while the power is supplied. Power–on time
[ RUN ] Count while operation is under way. Operating
[ CUT ] Count while cutting is under way. Cutting