F. FSSB START–UP PROCEDURE/
MATERIALS
B–63835EN/03
APPENDIX
670
Alarms related to servo amplifiers
NC
alarm
No.
Message Description
460 n AXIS : FSSB DISCON-
NECT
FSSB communication was disconnected
suddenly. The possible causes are as fol-
lows:
1) The FSSB communication cable is dis-
connected or broken.
2) The power to the amplifier dropped sud-
denly.
3) The amplifier issued a low–voltage
alarm.
461 n AXIS : ILLEGAL AMP IN-
TERFACE
Both axes of a 2–axis amplifier were as-
signed to the fast type interface.
462 n AXIS : SEND CNC DATA
FAILED
Because of an FSSB communication error, a
slave could not receive correct data.
463 n AXIS : SEND SLAVE DATA
FAILED
Because of an FSSB communication error,
the servo system could not receive correct
data.
466 n AXIS : MOTOR/AMP COM-
BINATION
The maximum current value of the amplifier
does not match the maximum current value
of the motor.
467 n AXIS : ILLEGAL SETTING
OF AXIS
The following servo functions are not en-
abled even when an axis using a DSP ex-
clusively is set on the axis setting screen:
1) Learning control (bit 5 of parameter No.
2008 = 1)
2) High–speed current loop (bit 0 of param-
eter No. 2004 = 1)
3) High–speed interface axis (bit 4 of pa-
rameter No. 2005 = 1)
468 HI HRV SETTING ER-
ROR(AMP)
Use of high–speed HRV is specified for a
controlled axis of an amplifier which does
not support high–speed HRV.