B–63835EN/03
1. DISPLAY AND OPERATION
29
#7
3112
#6 #5 #4 #3
EAH
#2 #1 #0
[Data type] Bit
#3 (EAH) The alarm history function:
0 : Does not record the messages output with external alarms or macro
alarms.
1 : Records the messages output with external alarms or macro alarms.
Up to three system alarms issued in the past are stored, and information
about those alarms can be displayed on the system alarm history screen.
SYSTEM ALARM HISTORY O1234 N12345
1 2002–03–13 12:13:19
930 CPU INTERRUPT
2 2002–03–11 07:23:07
900 ROM PARITY
3 2002–02–27
973 NON MASK INTERRUPT
EDIT **** *** *** 08:20:52
[ ][ ][ NMIHIS ][ ][ ]
By setting bit 2 (NMH) of parameter No. 3103 to 1, information about up
to three system alarms including the latest system alarm can be displayed.
The latest system alarm information is displayed at the top of the list, and
a lower item in the list indicates older system alarm information.
1 Set bit 2 (NMH) of parameter No. 3103 to 1.
2 Press the function key <MESSAGE>.
3 Press the [NMIHIS] chapter selection soft key.
The following information is displayed:
1. System alarm occurrence date and time
2. System alarm number
3. System alarm message (No message is displayed for some
system alarms.)
1.4.2
System Alarm History
1.4.2.1
General
1.4.2.2
System alarm history
screen (history list
screen)
Procedure