B–63835EN/03
4.INTERFACE BETWEEN CNC AND PMC
299
Display of an alarm when an alarm occurred in PMC program.
TITLE[][][][][]STATUS ALARM TRACE
PMC ALARM MESSAGE
ALARM NOTHING
MONIT RUN
See Appendix A.2 for details of the alarms.
Record the signal status to the trace memory when the specified signal is
changed.
(1)Trace parameter screen (TRCPRM)
T.DISP
[][][][][]
EXEC
PMC SIGNAL TRACE
MONIT RUN
TRACE MODE :
(0:1BYTE/1:2BYTE/2:WORD)
1ST TRACE ADDRESS CONDITION
ADDRESS TYPE : (0:PMC/1:PHY)
ADDRESS :
MASK DATA
2ND TRACE ADDRESS CONDITION
ADDRESS TYPE : (0:PMC/1:PHY)
ADDRESS :
MASK DATA :
(a) TRACE MODE: Select the trace mode.
0= 1 byte address signal trace
1= Independent 2 byte address signal trace
2= Continuous 2 byte address signal trace
(b)ADDRESS TYPE: 0= Set the trace address by PMC address
1= Set the trace address by physical address
(Using mainly by C language)
(c) ADDRESS : Set the trace address
(d)MASK DATA : Specify the trace bit by hexadecimal code.
For example, set the “E1” when trace the bit
7, 6, 5 and 0. Not execute the tracing when the
bit 4, 3, 2 and 1 is changed, but, the signal
status should recorded at tracing time.
(e.g) #7 #6 #5 #4 #3 #2 #1 #0
1 1 1 0 0 0 0 1:E1
4.3.3.3
Alarm screen (ALARM)
4.3.3.4
Trace screen (TRACE)