4. INTERFACE BETWEEN CNC AND PMC
B–63835EN/03
332
Address used by the
sequence program
(i) Nonvolatile memory control
#7
MWRTF2K16
#6
MWRTF1
#5 #4 #3 #2 #1 #0
#7 MWRTF2 This operation is performed for checking the writing status of the
nonvolatile memory.
#6 MWRTF1 Writing status in nonvolatile memory
(ii)PMC system parameters
The keep relays below are used by the system, so that the keep relays
cannot be used by the sequence program.
#7
DTBLDSPK900
#6 #5 #4
MEMINP
#3 #2
AUTORUN
#1
PRGRAM
#0
LADMASK
#0 LADMASK 0 : Access by the sequence program is enabled.
1 : Access by the sequence program is disabled.
#1 PRGRAM 0 : The built–in programmer function does not operate.
(Also, the programmer menu is not displayed.)
1 : The built–in programmer function operates.
(The programmer menu is displayed.)
#2 AUTORUN 0 : The sequence program automatically starts at power on.
1 : Pressing the soft key to sequence program execution starts the
sequence program.
#4 MEMINP 0 : The forcing function and override function are disabled.
1 : The forcing function and override function are enabled.
4.4.4.4
KEEP RELAY screen