B–63835EN/03
F. FSSB START–UP PROCEDURE/
MATERIALS
APPENDIX
659
Step 5 Enter the axis numbers on the amplifier setting screen.
(AMPLIFIER SETTING)
No. AMP SERIES UNIT CUR. [AXIS] NAME
1A1–L α SVM 40A [ 2 ] Z
2A2–L α SVM 40A [ 1 ] X
3A3–L α SVM 40A [ 4 ] A
4A3–M α SVM 80A [ 3 ] Y
NO. EXTRA TYPE PCB ID
>
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
Step 6 Press soft key [SETING]. (This soft key appears when a value
is entered.)
Step 7 Press function key
SYSTEM
.
Step 8 Pressing the continuous menu key
several times displays
[FSSB].
Step 9 Pressing soft key [FSSB] switches the screen display to the
amplifier setting screen, and displays the following soft keys:
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
Step 10 Press soft key [AXIS].
Step 11 Set the Cs contour axis on the axis setting screen. (Cs)
(AXIS SETTING)
AXIS NAME AMP M1 M2 1DSP Cs TNDM
1XA2–L0 0 0 0 0
2ZA1–L0 0 0 0 0
3C – 0001 0
4YA3–M0 0 0 0 0
5AA3–L0 0 0 0 0
>
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
Step 12 Press soft key [SETING]. (This soft key appears when a value
is entered.)
Step 13 Turn off then on the power to the CNC. This completes the
setting.