6. AC SPINDLE (SERIAL INTERFACE)
B–63835EN/03
434
In the αi spindle system, ID information output from each of the
connected units is obtained and output to the CNC screen.
The units that have ID information are shown below.
(Remark: Some instances of these units do not have ID information.)
S Spindle motor
S Spindle amplifier
S Power supply module
ID information is automatically read from each of the connected units
during first startup of the CNC and then recorded. During second or later
startup, the ID information recorded during first startup can be compared
with the ID information read this time on the screen to check whether the
configuration of the connected units is changed. (If there is a difference
between them, the alarm mark (*) appears.)
The recorded ID information can be edited. Therefore, the ID information
of an unit that does not have ID information can be displayed. (However,
the alarm mark (*) indicating a difference between these IDs appears.)
#7
13112
#6 #5 #4 #3 #2
SPI
#1 #0
IDW
[Data type] Bit
IDW The edit of the servo information screen or the spindle information screen
is:
0 : Prohibited
1 : Allowed
SPI The spindle information screen is:
0 : Displayed
1 : Not displayed
7.1.5
αi Spindle Information
Screen
General
Parameter