9.DIAGNOSIS B-63494EN/02
- 162 -
<2> DI/DO-related data
[Page 2]
• The states of input signals transferred via the PMC and FSSB are
displayed when a dual check safety alarm is issued. If no alarm
is issued yet, "0" is displayed for all data items.
• For a mismatching signal, "#" is prefixed to the address.
• The screen layout is the same as for page 2 of (1) current
machine state display.
• The related alarms are:
SV486 (CNC detection), SV479 (monitor detection)
[Page 3]
• The states of output signals transferred via the CNC and FSSB
are displayed when a dual check safety alarm is issued. If no
alarm is issued yet, "0" is displayed for all data items.
• For a mismatching signal, "#" is prefixed to the address.
• The screen layout is the same as for page 3 of (1) current
machine state display.
• The related alarms are:
SV493 (CNC detection), SV485 (monitor detection)
<3> Machine information
[Page 4] (Machine coordinates)
• The machine coordinates (detection unit) on the CNC and
monitor sides are displayed when a dual check safety alarm is
issued. If no alarm is issued yet, "0" is displayed for all data
items.
• A blank is displayed for all axes with dual check safety disabled.
• For an axis not within the safety area, the data is suffixed with
"#".
• The screen layout is the same as for page 6 of (1) current
machine state display.
• The related alarms are:
CNC → SV495
Monitor → SV477
[Page 5] (Positional deviation)
• The positional deviations (detection unit) on the CNC and
monitor sides are displayed when a dual check safety alarm is
issued. If no alarm is issued yet, "0" is displayed for all data
items.
• A blank is displayed for all axes with dual check safety disabled.
• For an axis exceeding the positional deviation, the data is
suffixed with "#".
• The screen layout is the same as for page 7 of (1) current
machine state display.
• The related alarms are:
CNC → SV410, SV411
Monitor → SV474, SV475