3.SAFETY FUNCTIONS B-63494EN/02
- 24 -
This section briefly describes the signals. For details, see Chapter 5,
"OPERATION." For specific connections, see the sample system
configuration in Chapter 10.
CNC
CPU
Monitor
CPU
I/O LINK
FSSB
I/O UNIT
FSSB I/O
DI
DI
DO
DO
Cross check
Machine
CNC
Duplicated I/O
Symbol Signal name I/O address
*ESP Emergency stop signal <X008#4> <DI+000#0> Dual input monitoring
SGD
SGD2
SGD3
SGD4
Guard state signal
Guard 2 state signal
Guard 3 state signal
Guard 4 state signal
<G191#4> <DI+001#4>
<G332#1> <DI+000#1>
<G332#2> <DI+000#2>
<G332#3> <DI+000#3>
Dual input monitoring
GDL Guard lock state signal <G191#5> <DI+001#5> Dual input monitoring
*SMC MCC contact state signal <G191#6> <DI+001#6> Dual input monitoring
SDI00 to SDI15 Programmable safe-related input signal <G334,G335>
<DI+002,DI+003>
Dual input monitoring
SVA1 to SVA8 Safety speed / safety position selection
signal A (for each axis)
<G336><DI+004> Dual input monitoring
SVB1 to SVB8 Safety speed / safety position selection
signal B (for each axis)
<G337><DI+005> Dual input monitoring
SPA1 to SPA4 Safety speed selection signal A
(for each spindle)
<G338#0 to #3>
<DI+006#0 to #3>
Dual input monitoring
SPB1 to SPB4 Safety speed selection signal B
(for each spindle)
<G338#4 to #7>
<DI+006#4 to #7>
Dual input monitoring
MCF MCC on enable signal <F191#1> <DO+000#1> Duplicated output
SDO00 to SDO07 Programmable safe-related output signal <G331><DO+001> Duplicated output
SPS01 to SPS32 Safety Position Switch signal <F336 to F339>
<DO+002 to DO+005>
Duplicated output
ORQ
ORQ2
ORQ3
ORQ4
Guard open request signal
Guard 2 open request signal
Guard 3 open request signal
Guard 4 open request signal
<G191#3>
<G350#0>
<G350#1>
<G350#2>
Input
OPT Test mode signal <G191#2> Input
*LGD
*LGD2
*LGD3
*LGD4
Guard unlock signal
Guard 2 unlock signal
Guard 3 unlock signal
Guard 4 unlock signal
<F191#0>
<F350#0>
<F350#1>
<F350#2>
Output
RQT MCC off Test execution request signal <F191#2> Output