B–70115EN/03
6. TROUBLESHOOTING
170
(2)Inverter (A90L–0001–0464/CE, 0465/CE: Model JH300)
When an alarm is issued, the digital panel displays a message
indicating the type of alarm. The table below lists the messages,
descriptions, and causes.
Message Description Cause
E01 Overcurrent during turbo blower
constant–speed operation
Turbo blower rotor
locked
E02 Overcurrent during turbo blower decel-
eration
Motor short–circuited or
ground–fault
E03 Overcurrent during turbo blower accel-
eration
E04 Overcurrent when turbo blower is not
operating
Inverter CT faulty
E05 Inverter overload (overload operation)
E06 Regenerative braking operation time
exceeding the setting
Invalid inverter setting
Turbo blower faulty
E07 Direct current smoothing circuit overcur-
rent
Inverter faulty
E08 EEPROM error
E09 Abnormal power supply (voltage drop) Supply voltage drop
E10 CT error
Inverter faulty
E11 CPU error
E12 Alarm related to external trip function
E13 Alarm related to function for preventing
restart by repower operation
E14 Inverter output side ground–fault Turbo blower or wiring
ground–fault
E15 High received voltage (supply voltage
increase)
Increased supply volt-
age
E16 Abnormal power supply (momentary
loss)
Momentary loss of sup-
ply voltage
E17 Option board 1 connection abnormal
Inverter faulty
E18 Option board 2 connection abnormal
E19 Option board 1 abnormal
E20 Option board 2 abnormal
E31 Abnormal temperature during turbo
blower constant–speed operation
E32 Abnormal temperature during turbo
blower deceleration
E33 Abnormal temperature during turbo
blower acceleration
E34 Abnormal temperature when turbo
blower is not operating