B–70115EN/03
D. PARAMETERSAPPENDIX
413
0232 LPCMD3
LPCMD3 Power command for power calibration in mode of 8 discharge tubes.
This is power command for power calibration in mode of 8 discharge
tubes.
Duty is 100%.
[Setting range] 0 to 32767
[Unit] WATT
[Standard setting] Refer to the parameter data sheet delivered with the machine
15203 MRLMT
MRLMT0240
MRLMT Power calibration limit
This is upper limit of power calibration When the value set for exceeds
this value, alarm appears and warms the decrease of laser power.
[Setting range] 0 to 32767
[Unit] 1/1024
[Standard setting] 1150
15204 CAL
CAL0241
CAL Power calibration coefficient
This is to calibrate command power for real power. This parameter is
automatically set in power calibration after RUN start.
[Setting range] 0 to 32767
[Standard setting] (automatic setting)
15205 PCLBTM
PCLBTM3991
PCLBTM Power calibration time
Set a power calibration time.
[Setting range] 0 to 32767
[Unit] sec
[Standard setting] 180
15206 LPWRTC
LPWRTC Time constant of the filter used for laser power variation suppression
If a value less than 8 is specified, the filter does not function.
[Setting range] 0 to 32767
[Unit] msec