B–70115EN/03
9. SETTING AND ADJUSTMENT
242
(1)Start the oscillator, and wait 10 minutes in the LRDY state. Then set
HV ON and wait until the gas pressure is stabilized in the base
discharge state. (Wait about 3 minutes. See DGN 905 [16–L, 16i–L]
or DGN 860 [0–L].) Check that all discharge tubes are continuously
discharging. If a discharge tube stops discharge, turn VR11 of the
power supply corresponding to the discharge tube clockwise until the
discharge tube discharges.
(2)Turn VR11 of power supply 1 counterclockwise so that the discharge
tube is discharging in the state immediately before stopping discharge.
Adjust power supply 2 for discharge tube 3, adjust power supply 3 for
discharge tube 4, adjust power supply 4 for discharge tubes 5 and 6 in
the same way as for power supply 1.
(3)Record the value of RFI or the values of RFI and DCV. (See Note 1.)
(a). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(1)Check that discharge continues for 30 minutes after adjustment. If a
discharge tube stops discharge (C2000B, C3000C) or blinks (C1500B
(without a trigger electrode)), turn VR11 of the power supply
gradually clockwise to increase the value of RFI by 4 mA or the value
of DCV by 0.7 V. Set HV OFF then set HV ON to check that discharge
continues 30 minutes. Repeat this until checking that discharge
continues 30 minutes.
(2)Set HV OFF, return the value of parameter No. 15242 and No. 15243
[16–L, 16i–L] or parameter No. 236 [0–L] (intra–tube pressure setting
at oscillation time) to the original value (Note 2), and wait until the gas
pressure is stabilized in the base discharge state.
(3)Adjust VR11 to increase the value of Iplus RFI or the value of Vplus
DCV. (See Note 4.)
(4)Record the value of RFI or the values of RFI and DCV. (See Note 1.)
(A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(1)Start the oscillator, and wait 10 minutes in the LRDY state. Then set
HV ON and wait until the gas pressure is stabilized in the base
discharge state. (Wait about 3 minutes. See DGN 905 [16–L, 16i–L]
or DGN 860 [0–L].)
(2)Adjust VR11 of power supply 1 so that discharge tubes 1 and 2
discharge up to the point indicated by the arrow shown below. Adjust
power supply 2 for discharge tube 3, power supply 3 for discharge tube
4, power supply 4 for discharge tubes 5 and 6, power supply 5 for
discharge tubes 7 and 8, power supply 6 for discharge tube 9, power
supply 7 for discharge tube 10, and power supply 8 for discharge tubes
11 and 12 in the same way as for power supply 1.
9.1.2.3
C3000C (step 1)
9.1.2.4
C2000B, C3000C (step 2)
9.1.2.5
C6000B