B–70115EN/03
9. SETTING AND ADJUSTMENT
248
NOTE
4 Settings for each oscillator
5 Setting pins
C1500B C2000B C3000C C3000C C6000B C6000B
without a trigger (No.1, 4 PSU) (No.2, 3 PSU) (No. 1, 4, 5, 8 No. 2, 3, 6, 7
electrode PSU) PSU)
S2 setting B201 B202 B201 B202 B202 B201
S5 setting SHORT SHORT SHORT SHORT USUAL SHORT
Iplus )12mA )10mA )20mA
Vplus )2.0V )0.7V )3.5V )1.5V
Maximum command PRM15307 PRM15304 PRM15307 PRM15307 PRM15307 PRM15307
value
Maximum power 6200"50W 4400"50W 6600"50W 4400"50W 8000"50W 4000"50W
supply output
DCI DCV+
Maximum base +0W +0W Note 3 Note 3 t100W t100W
output
Maximum RFV t4600V t4800V t4600V t4600V t4600V t4600V
Pulse test command Maximum PRM15305 Maximum Maximum Maximum Maximum
command value command value command value command value command value
Pulse test time u10 min u10 min u30 min u30 min u30 min u30 min
C1500B C2000C C3000D C4000A
with a trigger
electrode
S2 setting B201 B201 B201 B201
S5 setting USUAL USUAL USUAL USUAL
Electric shutter 250mA 180mA 250mA
adjustment
Maximum command PRM15306 PRM15306 PRM15307 PRM15307
value
Maximum power 5400"50W 7800"50W 8000"50W 8300"50W
supply output
DCI DCV+
Maximum RFV t4600V t4800V t4600V t4600V
Pulse test command Maximum Maximum Maximum Maximum
command value command value command value command value
Pulse test time u30 min u30 min u30 min u30 min
VR13 VR11
LED1
LED2
Usual
Short
S2
CP73
CP51
CN18
CN17
B201
B202
S5
Setting pin
Power supply alarm LED
Location of setting pin S2 Details of S5 Details of S2
Locations of setting pins S5 and S2, and monitor connectors CN17 and CN18