APPENDIX
B–70115EN/03
D. PARAMETERS
420
15248 GPNRAV
GPNRAV4399
GPNRAV Allowable gas pressure insufficiency
The insufficient gas pressure alarm is issued when the gas pressure in the
discharge tube does not reach [(specified tube pressure for oscillation) –
(this allowable value)].
[Setting range] 0 to 32767
[Unit] 13 Pa
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15249 GPRST
GPRST Gas pressure increase time
This parameter specifies a gas pressure increase time in sequence 27.
[Setting range] 0 to 32767
[Unit] sec
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15255 VENWT
VENWT3994
VENWT RUN ON evacuation time
This parameter specifies the time between the three–way valve being
opened and the exhaust valve being opened, when the laser is turned on.
[Setting range] 0 to 32767
[Units] sec
[Standard setting] Refer to the parameter data sheet delivered with the machine.
15256 GEVWT
GEVWT3995
GEVWT RUN OFF evacuation time
When the oscillator is turned off, the gear box is evacuated prior to purge.
This parameter specifies the time required for evacuation. The minimum
time is fixed to 600 seconds. Therefore, specify a value of at least 600.
[Setting range] 600 to 32767
[Units] sec
[Standard setting] 900