B–62884EN/01
3. OPERATION
95
(1) Outline of Signal Analysis Function
The changes in a PMC ladder signal can be traced on the specified
trigger conditions. Displaying the results of tracing signals on a time
axis enables checking the relationship between the signals.
D Maximum number of signals traced at the same time : 16
D Maximum sampling period : 10 sec
D Sampling interval : 8 msec
(2) Operations
(a) Selection of Signal Analysis Screen
Ladder Monitor
Signal Status
PMC Parameter
PMC alarm status
PMC Status
RUN/STOP the program
Signal Trace
Signal Analysis
System Information
2. Diagnose
F1
Exec
Signal analysis
Sampling Time : 10 (sec) Condition : Trigger–ON
Trigger Address : *ESP Trigger Mode : ABOUT
Start Time 1996/01/30 10:11:12 Stop Time 1996/01/30 10:11:22
STOP
F3
Sgnprm
R0901.0
R0901.3
R0901.2
R0901.1
512 1024(msec)
F2
T.Srch
F6
Exchg
F10
SgnSet
Fig.3.4.3.8 Screen of Signal Analysis Function
(b) Setting of Analysis Parameter
Analysis Parameter dialog is displayed by pressing F3“Sgnprm”.
3.4.3.8
Signal Analysis Function