A. FUNCTIONS SPECIFIC TO INDIVIDUAL
PMC MODELS
B–62884EN/01
286
(c) Starting link processing
[Operation]
1) Press
F4
on the utility screen.
2) Then, the pop-up screen shown below appears. Pressing the
Enter
key displays the link screen.
EXEC FILE NAME
i _lipmcr – p fl03400. tbl
↑
Model file name
Specify the model to be used for link processing, by changing the
model file name.
The table below indicates the correspondence between the PMC
models and model file names.
PMC model Model file name
PMC-RC3
PMC-RC4
PMC-RC4 (STEP SEQ)
fl03400.tbl (Initial value)
fl04000.tbl
fl04200.tbl
3) The link screen appears.
Linker PMC–RC3 <0>[A:¥FLADDER¥]
1 EXEC 2 MAP 3 ERROR 4 P 5 I 6 7 8 9 10 END
Load module file name : A:¥DATA¥C–MODULE.SR
ROM format file name : A:¥DATA¥SAMPLE.#EX
Series Edition Machine tool name
NC & PMC name Program no.
Note
If an invalid model file is specified, the status line of the link
screen does not display a model name. In such a case,
check the following:
· When the newly entered file name is invalid
→
Enter a valid file name.
· When the specified model file is not installed
→ Install the model file.