B–62884EN/01
3. OPERATION
63
Trigger Parameter
OK
F Level1
f END1
f END2
f END3
Check–Point
Address
X1000.0
Count
65535
f ON
F OFF
Trigger–Mode
InitCancel
[Trigger Parameter DIALOG]
Please set the following items by “Trigger Parameter” dialog.
1) Address: Trigger address (Symbol is possible.)
2) Check Point: Trigger check point
LEVEL1(Default) the top of the 1st level (Default)
END1 after END1 execution
END2 after END2 execution
END3 after END3 execution
3) Count: Trigger count(1 to 65535)
4) Trigger Mode: Trigger condition
ON Rising edge detection
OFF Falling edge detection
When [Init] is selected, parameter and the display data are
initialized.
Please select [OK] when setting is completed.
Please select [Cancel] or press the Esc key when you cancel
setting.
(c) Starting or stopping signal trigger function
Please press F1“Exec” or “Stop” in Fig.3.4.3.1.3 (a).Screen of
Signal Trigger Function.
(d) Search of the instruction when the trigger condition was satisfied
Please press F2“T.Srch”.
The instruction when the trigger condition was satisfied is
displayed in blue.