B–63523EN/03
5. CONNECTION TO CNC PERIPHERALS
89
Feed power to the MDI unit from an external 24 VDC power supply.
1 +24V
2 0V
3
CPD1
(AMP)
1
2
+24V
+24VDC ±10%
0V
0V
CPD1
FG
MDI unit
External power supply
+24 VDC power supply
(regulated power supply)
+24 VDC ±10%
AMP Japan
1–178288–3 (housing)
1–175218–5 (contact)
FANUC purchase specification: A02B–0120–K324
Cable connections
Recommended wire: 30/0.18 (0.8 mm
2
) or more
Recommended cable specification: A02B–0124–K830 (5 m)
(On the external power supply side, an M3 crimp terminal is provided.)
Power is fed from an external 24 VDC power supply to the LCD unit
through the MDI unit.
With an LCD/MDI integration unit, the connection of a power supply to
the LCD unit is enclosed inside the unit, so that the machine tool builder
need not make any connections.
1 +24V
2 0V
3
CPD2
(AMP)
1
2
+24V
+24V
0V
0V
CPD2
FG
1 +24V
2 0V
3
CP5
(AMP)
1
2
CP5
MDI Unit LCD Unit
AMP Japan
2–178288–3
(housing)
1–175218–5
(contact)
AMP Japan
1–178288–3 (housing)
1–175218–5 (contact)
Cable connections
Recommended cable: A02B–0166–K880 (55 cm)
D Connection of a power
supply to the MDI unit
D Connection of a power
supply to the LCD unit