B–63523EN/03
9. CONNECTION TO FANUC I/O Link
377
Main panel A/B/A1/B1
Cable Terminal Manual pulse generator
1 HA1 11
2 HB1 12 0V
3 HA2 13
4 HB2 14 0V
5 HA3 15
6 HB3 16 0V
717
8 18 +5V
9 +5V 19
10 20 +5V
3456
+5V 0V HA1 HB1
3456
+5V 0V HA1 HB1
3456
+5V 0V HA1 HB1
JA3
HA1
HB1
+5V
0V
HA2
HB2
+5V
0V
HA3
HB3
+5V
0V
1
2
9
12
3
4
18
14
5
6
20
16
7BK
7WH
5RD
5BK
8RD
8BK
4RD
3BK
9BK
9WH
6RD
1BK
#1
#2
#3
Groun
Cable
HA1
HB1
+5V
0V
HA2
HB2
+5V
0V
HA3
HB3
+5V
0V
Wiring
5
6
3
4
5
6
3
4
5
6
3
4
HA1
HB1
+5V
0V
HA2
HB2
+5V
0V
HA3
HB3
+5V
0V
When the depth of the operator’s panel is 80mm min.
Recommended wire material : A66L–0001–0286(#20AWGx6+#24AWGx3pairs)
Recommended connector : A02B–0120–K303(Including below connector and case)
(Connector : HIROSE FI40B–2015S Soldering type)
(Case : HIROSE FI–20–CV)
Recommended cable : A02B–0120–K841(7m) (MPG 3 units)
A02B–0120–K848(7m) (MPG 2 units)
A02B–0120–K847(7m) (MPG 1 unit)
(These cables don’t include the wiring part in the figure.)
When the depth of the operator’s panel is 60mm min.
Recommended wire material : A66L–0001–0284#10P(#28AWGx10pairs)
Recommended connector : A02B–0236–K302(Including below connector and case)
(Connector : HIROSE FI30–20S Stand wire press–mount type)
(Case : HIROSE FI–20–CV7)
Manual pulse generator # 1
(M3 Screw)
Manual pulse generator # 2
(M3 Screw)
Manual pulse generator # 3
(M3 Screw)
NOTE
Calculate the MPG cable max. Length as refer to the
following calculation.