9. CONNECTION TO FANUC I/O Link
B–63523EN/03
338
(3)When an emergency stop signal is output to other I/O
Other I/O
Machine operator’s panel
Printed circuit board
Receiver
Receiver
NOTE
In the examples (1) and (2) above, an emergency stop
signal is applied to the DI address (Xm+2.4) tied to the 24V
common signal. So, allocate DI addresses as described in
Section 9.12.12. For details of the wiring used to apply an
emergency stop signal to a DI address other than Xm+2.4,
see Sections 9.12.6 and 9.12.12. In the example of (3),
Xm+2.4 can be used as a general–purpose DI address.
The machine operator’s panel has 24 general–purpose DI points. The
interface is as follows:
Connector recommended for use on the CM58 cable side:
HIF3BA–34D–2.54R (Hirose Electric)
9.12.6
General–purpose DI
Signal Connection