9. CONNECTION TO FANUC I/O Link
B–63523EN/03
364
Machine operator’s panel is connected with i series CNC by I/O Link,
which is composed by some following operator’s panels.
Main panel A/A1
This operator’s panel incorporated with MDI with full alphabet keys.
And that has 55 keys. All key tops are detachable. MTB can customize
keys and make his original key layout easily.
Main panel B/B1
The part of keyboard of machine operation in Main panel A.
Sub panel A
This operator’s panel has power ON/OFF, emergency stop, program
protect, and two rotary switches.
Sub panel B
This operator’s panel has emergency stop, program protect, and rotary
switch.
Sub panel C
This operator’s panel has power ON/OFF, emergency stop, program
protect, rotary switch, and MPG.
Sub panel B1
This operator’s panel has emergency stop, program protect, two rotary
switches.
Sub panel C1
This operator’s panel has emergency stop, program protect, two rotary
switches, and MPG.
9.13
CONNECTION TO
MACHINE
OPERATOR’S PANEL
9.13.1
Overview