B--63003EN--1/02
11. PROGRAM COMMAND
993
#7 #6 #5 #4 #3 #2 #1 #0
*BECLPG038 *BEUCP
#7 #6 #5 #4 #3 #2 #1 #0
F061 BCLP BUCLP
#7 #6 #5 #4 #3 #2 #1 #0
1006 ROSx ROTx
NOTE
When this parameter is changed, turn off the power before
continuing operation.
[Data type] Bit axis
ROTx, ROSx Setting linear or rotation axis
ROSx ROTx Description
0 0
Linear axis
D Inch/metric conversion is done.
D All coordinate values are linear axis type.
(Not rounded in 0 to 360_)
D Stored pitch error compensation is linear axis type (Refer toparame-
ter No. 3624)
0 1
Rotation axis (A Type)
D Inch/metric conversion is not done.
D Machine coordinate values are rounded in 0 to 360_. Absolute coor-
dinate values and relative coordinate values are
rounded or not rounded by parameter No. 1008 #0 and #2.
D Stored pitch error compensation is the rotation type. Refer to param-
eter No. 3624.
D Automatic reference position return (G28, G30) is done in the refer-
ence position return direction and the move amount does not exceed
one rotation.
1 0
Setting is invalid (unused)
1 1
Rotation axis (B type)
D Inch/metric conversion is not done.
D Machine coordinate values absolute coordinate values and relative
coordinate values are linear axis type and is not rounded in 0 to 360_.
D Stored pitch error compensation is linear axis type (Refer to parame-
ter No. 3624)
D Cannot be used with the rotation axis roll over function and the index
table indexing function (M series).
Signal address
Parameter
D Setting linear or rotation
axis