B--63003EN--1/02
1. AXIS CONTROL
59
When the power is switched on, values are read from the parameters and
displayed on the screen.
NOTE
1 For the parameters to be specified on the FSSB setting
screen, do not attempt to enter values on the parameter
screen using the MDI or a G10 command. Use only the
FSSB screen to enter values for these parameters.
2 If pressing the [SETING] key results in a warning message
being displayed, retry data entry, or pressthe [CANCEL] key
to clear the warning message. Note that pressing the reset
key does not clear the warning message.
(1)Amplifier setting screen
AMPLIFIER SETING O1000 N00001
NO. AMP SERIES UNIT CUR. AXIS NAME
1 A1-L ∼ SVM-HV 40AL 1 X
2 A1-M ∼ SVM 12A 2 Y
3 A2-L ϒ SVM 40A 3 Z
4 A3-L ∼ SVM 20A 4 A
5 A3-M ∼ SVM 40A 5 B
7 A4-L ∼ SVU 240A 6 C
NO. EXTRA TYPE PCB ID
6 M1 A 0000 DETECTOR(8AXES)
8 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][ (OPRT) ]
The amplifier setting screen displays the following items:
D AXIS controlled axis number...
For this item, enter a value of between 1 and the maximum number
of controlled axes. If a number that falls outside this range is
entered, the warning message FORMAT ERROR appears. If the
entered controlled axis number is duplicate or 0, the warning
message DATA IS OUT OF RANGE appears when the [SETING]
soft key is pressed to assert the entered value. In this case, no value
can be entered for the parameter.