12. DISPLAY/SET/EDIT
B--63003EN--1/02
1034
3120 Time from the output of an alarm to the termination of sampling (waveform diagno-
sis function)
[Data type] Word
[Unitofdata] ms
[Valid data range] 1 to 32760
This parameter specifies the time allowed from the time a servo alarm
condition occurs until data collection and recording are stopped in the
waveform diagnosis function; data collection can be continued
additionally for the specified time.
NOTE
1 Once the memory area becomes full, the oldest data is
deleted to allow new data to be recorded (stored type).
2 Waveform diagnosis data is held in memory even after the
power is turned off (stored type).
3 Be careful to set the date and time correctly.
4 To output stored type waveform data, the reader/punch
interface option is required.
5 Waveform diagnosis is enabled when bit 0 (SGD) of
parameter No. 3112 is set to 1. To perform waveform
diagnosis, a graphics card is required.
Usual graphic display function can not be used when
waveform diagnosis function is enable.
Series
16i/160i/18i/180i/
21i/210i/20i
MAINTENANCE MANUAL
(B--63005EN)
1.10 Waveform diagnostic display
Note
Reference item