B--63003EN--1/02
15. PMC CONTROL FUNCTION
1231
NOTE
This signal is set to “0” when distribution for the axis is
completed (the signal is set to “0” during deceleration).
[Classification] Output signal
[Function] When an auxiliary function (EC0g to EC6g: 12h) is specified by the
PMC, this signal is set to “1” during the period from when auxiliary
function codes EID0g to EID15g are sent to auxiliary function code
signals EM11g to EM48g until auxiliary function completion signal
EFINg is returned.
The timing chart for the command operation is shown below.
Command block
(input)
EM11gtoEM48g
(output)
EMFg, EMF2g, EMF3g
(output)
EFINg
(input)
EDENg
(output)
Auxiliary function command Next command
TFIN
TMF
TMF and TFIN are set with parameters No. 3010 and 3011.
[Classification] Output signal
[Function] These signals are set to “1” when an overtravel alarm is detected. When
the stroke limit in the negative direction is exceeded, signal EOTNg is set
to “1”. When the stroke limit in the positive direction is exceeded, signal
EOTPg is set to “1”. Simultaneously, alarm signal EIALg is set to “1”.
23 Auxiliary fu nction
executing signal
EDENg
24 Negative--d irection
overtravel sign al
EOTNg
25 Positive--direction
overtravel sign al
EOTPg