B--63003EN--1/02
5. AUTOMATIC OPERAT ION
443
#7 #6 #5 #4 #3 #2 #1 #0
G043
F003
DNCI
MRMT
#7 #6 #5 #4 #3 #2 #1 #0
#7 #6 #5 #4 #3 #2 #1 #0
0100 ND3
Setting entry is accepted.
[Data type] Bit
ND3 In DNC operation, a program is:
0 : Read block by block. (A “DC3” code is output for each block.)
1 : Read continuously until the buffer becomes full. (A “DC3” code is
output when the buffer becomes full.)
NOTE
In general, reading is performed more efficiently when
ND3=1. This specification reduces the number of buffering
interruptions caused by reading of a series of blocks
specifying short movements. This reduces the cycle time.
Number Message Description
086 DR SIGNAL OFF When entering data in the memory by
using Reader / Puncher interface, the
ready signal (DR) of reader / puncher
was off.
Power supply of I/O unit is off or cable
is not connected or a P.C.B. is defec-
tive.
123 CAN NOT USE MACRO
COMMAND IN DNC
Macro control c ommand is used during
DNC operation.
Modify the program.
210 CAN NOT COMAND
M198/M99
M198 and M99 are executed in the
schedule operation. Or M198 is
executed in the DNC operation.
Signal address
Parameter
Alarm and message